交流高壓試驗機
符合(he)GB/T3048.8-2007電(dian)(dian)線電(dian)(dian)纜電(dian)(dian)性能試驗方法第8部分:交(jiao)流電(dian)(dian)壓(ya)試驗。GB/T 16927.1-1997 高電(dian)(dian)壓(ya)試驗技術 *部分: 一(yi)般試驗要求等標準。
交流高壓試驗機常規型號主要技術參數:
型號 | 輸入(ru)電壓 | 適(shi)配(pei)器容(rong)量(KVA) | 額定(ding)輸出電(dian)壓(KV) | 額定(ding)輸(shu)出電流(mA) |
GY-100/50 | 380V | 100KVA | 50KV | 2000 |
GY-50/100 | 380V | 50KVA | 100KV | 500 |
GY-50/10 | 380V | 50KVA | 10KV | 5000 |
GY-30/50 | 380V | 30KVA | 50KV | 600 |
GY-20/100 | 380V | 20KVA | 100KV | 200 |
GY-10/30 | 220V | 10KVA | 30KV | 330 |
GY-10/50 | 220V | 10KVA | 50KV | 200 |
GY-10/100 | 220V | 10KVA | 100KV | 100 |
GY-10/120 | 220V | 10KVA | 120KV | 80 |
GY-5/50 | 220V | 5KVA | 50KV | 100 |
GY-5/100 | 220V | 5KVA | 100KV | 50 |
其(qi)他(ta)型(xing)號根據客戶(hu)要求來定。
技術指標如下:
電壓波型(xing):正(zheng)弦(xian)波
電壓誤差:±3%
電壓(ya)顯(xian)示:數顯(xian)
系統組成:控制臺(tai)、調壓(ya)(ya)器、變壓(ya)(ya)器
試驗(yan)時間:0~9999min可設定
控制(zhi)(zhi)方式(shi):手動(dong)(dong)升(sheng)壓(ya)(手動(dong)(dong)控制(zhi)(zhi)臺(tai))/電(dian)動(dong)(dong)升(sheng)壓(ya)(點(dian)電(dian)動(dong)(dong)控制(zhi)(zhi)臺(tai))/全(quan)(quan)自動(dong)(dong)升(sheng)壓(ya)(全(quan)(quan)自動(dong)(dong)控制(zhi)(zhi)臺(tai))。
調(diao)壓器:自(zi)耦式
變壓(ya)器(qi):油(you)浸式試驗(yan)變壓(ya)器(qi)
保護(hu)(hu):過(guo)電流保護(hu)(hu)。